- Overview
- Detailed Photos
- Product Description
- Product List
- Company Profile
Basic Info.
Model NO.
PM70
Certification
ISO13485
Group
Adult,Pediatric,Neonata
Product Name
Desktop Blood Pressure Monitor NIBP/SpO2/ECG Monit
Parameters
ECG, SpO2, NIBP Pulse Rate
Warranty Period
18 Months for Main Unit and 6 Months for Accessory
Transport Package
Carton
Specification
ECG, SpO2, NIBP Pulse Rate
Trademark
Contec
Origin
Hebei, China
HS Code
9018193010
Production Capacity
100/Week
Product Description
CONTEC PM70 All-round monitoring for adult, pediatric and neonatal with button and small rechargeable touch screen patient monitor
Model:PM70 Brand:CONTEC
Standard parameter:ECG,SPO2,PR,NIBP
Features
1.3.5'' (320×240) TFT LCD
2.Operate with button and touch screen
3.Review of data list and trend graph
4.Configuring interface as user's requirements
5.Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set
6.Built-in rechargeable Li-polymer battery for uninterrupted monitoring
Performance
ECG
Blood Pressure
Spo2
Accessories
Standard:
1.Power adapter
2.ECG lead wire
3.SpO2 probe
4.Adult NIBP cuff
5.A base of the PM70
Optional:
Aceessaries of Pediatric and Neonatal accessaries
Physical characteristic of host
-Dimension: 145(W)*95(H)*37(D)mm
-Weight: 400g(including battery)
More information about Desktop Blood Pressure Monitor NIBP/Spo2/ECG Monitor Manufacturer-CONTEC MEDICAL SYSTEMS CO., LTD
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products
View more products,click here...
Model:PM70 Brand:CONTEC
Introduction
Desktop Blood Pressure Monitor NIBP/Spo2/ECG Monitor PM70 can be used for adult, pediatric and neonatal.Standard parameter:ECG,SPO2,PR,NIBP
Features
1.3.5'' (320×240) TFT LCD
2.Operate with button and touch screen
3.Review of data list and trend graph
4.Configuring interface as user's requirements
5.Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set
6.Built-in rechargeable Li-polymer battery for uninterrupted monitoring
Performance
ECG
Lead | 3-lead and 5-lead are optional |
Waveform display | dual-lead/full-lead |
Gain selection | 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV |
Measurement range for Heart rate(HR) | 30bpm~300bpm, error: ±1bpm or ±1%, whichever is greater |
Upper and lower limit for alarm range | 30bpm~300bpm, resolution: 1bpm |
Input current | ≤0.1μA |
Enduring polarization voltage | ±300mV, sensitivity range: ±5%. |
CMRR | filter mode(surgery, monitoring)≥80dB |
Frequency response | 1~75Hz(+0.4dB,-3dB) |
Low-frequency characteristic | time constant≥3.2s |
Analysis function | heart rate, arrhythmia analysis, S-T segment analysis |
S-T segment range | -2.0mV~2.0mV |
Blood Pressure
Measurement method | Oscillometry |
Measurement mode | manual/auto/continuous |
Auto measurement interval | adjustable from 1 to 90 minutes |
Resolution | 1mmHg |
Accuracy | Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg |
Overpressure protection | double protection for software and hardware |
Range | Adult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHg |
Pediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHg | |
Neonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHg | |
Upper and lower limit of alarm | Adult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHg |
Pediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHg | |
Neonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHg |
Spo2
SpO2 monitoring | Continuous real-time measuring Adopt digital SpO2 technology, which has strong anti-interference capability Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph Trend graph with the function of adaptive scaling Standard finger-clip probe for adult, binding probe for neonatal is optional |
SpO2 Measuring | Range: 0%~100% (Resolution: 1%) Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70% Pulse Rate Measuring Range: 30bpm~250bpm(Resolution: 1bpm) Accuracy: ±2bpm or ±2%, whichever is greater Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. |
Accessories
Standard:
1.Power adapter
2.ECG lead wire
3.SpO2 probe
4.Adult NIBP cuff
5.A base of the PM70
Optional:
Aceessaries of Pediatric and Neonatal accessaries
Physical characteristic of host
-Dimension: 145(W)*95(H)*37(D)mm
-Weight: 400g(including battery)
More information about Desktop Blood Pressure Monitor NIBP/Spo2/ECG Monitor Manufacturer-CONTEC MEDICAL SYSTEMS CO., LTD
-TELEMEDICINE products
-Pulse oximeter-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products